12 kHz to 50 Hz Meter Pulse Converter
The Siemens Meter Pulse Conversion Device is intended
for installation in telephone exchanges to provide conversion of 12 kHz
transverse metering pulses to 50 Hz longitudinal metering pulses. The system
consists of a 19” Sub-rack and
plug-in Detector/Generator Cards.
The key features include :
·
Entire circuitry contained on single card.
·
Continuous self test and alarm monitoring in both active and idle
states.
·
Low insertion loss ensures high quality of voice transmission.
·
No noise or clicks generated when meter pulses are inserted.
·
This product is widely used by Telstra.
Applications
·
Use for customer
equipment that operates only on 50 Hz metering.
·
Permits the use of
equipment requiring metering over long lines.
MPCD Sub-rack
·
Provides power, line and alarm connections.
·
Access to connectors made easy with a slide out panel.
·
The sub-rack can accommodate up to 12 MPCD Det/Gen cards.
·
Suitable for mounting in Type 84, Type 92, 19 inch and ETSI racks.
·
IDC terminals are provided for terminations
MPCD Det/Gen Card
·
Each card contains two meter pulse converters.
·
One common alarm output per card.
·
High suppression of 12 kHz signalling in the customer line.
·
Shaped pulses to eliminate transients.
·
A green “busy” LED lights when the line is in use.
·
A yellow LED pulses when a meter pulse is sent.
·
A red LED lights when an alarm is detected.
·
A push button is provided to check/clear alarm LEDs.
TECHNICAL
SPECIFICATIONS
12 Slot MPCD Sub-rack
Capacity 24 individual customer
lines
Power Supply -38.5 to -65
volts, -48V nominal
Supply Current 20 mA (without
cards), 2.42 Amps (all cards injecting 50 Hz).
Alarm output Earth or
Open Circuit, 2 Amps.
Line cable termination
sockets Insulation Displacement
Terminals
Dimensions H: 132.2
mm
W: 535 mm
(Type 92), 482 mm (Type 84 & 19” rack)
D: 218 mm
(with plug in card)
Weight 5.86
Kg (13 Kg with 12 MPCD Det/Gen Cards)
MPCD Det/Gen Card
Current consumption per
card 35 mA (Idle), 200 mA (both
channels injecting 50Hz)
12 kHz detection 11.9 kHz to 12.1
kHz
12 kHz suppression at
output >65 dB (200 W)
Input impedance 200 W (at 12 kHz)
50 Hz pulse ±1 Hz, injected longitudinally with
respect to earth
50 Hz duration 240±2 ms
50 Hz voltage 45±0.7 Vrms from 0 mA to 20 mA
Insertion Loss <0.6 dB
(600 W)
Transmission impedance 600 W over 300 to 3400 Hz. 200 W over 11.8 to 12.2 kHz
Return Loss >20 dB
(600 W)
Line Reversal Transparent
(40 ms maximum delay)
Line Busy Detection 10 ± 2 mA
Operating Temperature
Range -10oC to 60oC
(for all equipment)
Ordering Details Contact
Details
Item |
Part No |
Telstra SI |
|
Sales |
Siemens Australia |
Sub-rack |
20001660 |
279/239 |
|
Technical |
Peter Phillips |
Det/Gen Card |
20001681 |
279/240 |
|
|
+61 2 9491-5344 |